Technical data and specifications |
Reference standards | IEC 60252-1 |
Safety class according IEC 60252-1 | P2 |
Life expectancy to IEC 60252-1 | 3,000(C) ~ 10,000h(B) |
Rated capacitance CR | 2µF ~ 150µF (MFD) |
Tolerance | ± 5% |
Rated voltage VR | 110VAC ~ 630VAC |
Rated frequency FR | 50/60Hz |
Maximum permissible votage Vmax | 1.1 x VR (VR=Rated voltage) |
Maximum permissible current Imax | 1.3 x IR (IR=Rated current) |
AC test voltage terminal to terminal VTT | 2 x VR, 2s (routine test) |
2 x VR, 60s (type test) |
Insulation voltage terminal to case | 1.75 x VR, 2s (type test) |
1.75 x VR, 60s (routine test) |
Dissipation factor tan δ | ≤0.002 (50Hz) |
Climate types | 25/085/21 to IEC 60068-1 |